Коды ошибок кондиционеров Ballu

Коды ошибок кондиционеров Ballu Olympio Edge on/off

BSO/in-07HN8_22Y
BSO/in-09HN8_22Y
BSO/in-12HN8_22Y
BSO/in-18HN8_22Y
BSO/in-24HN8_22Y
BSO/out-07HN8_22Y
BSO/out-09HN8_22Y
BSO/out-12HN8_22Y
BSO/out-18HN8_22Y
BSO/out-24HN8_22Y

 OFF   E1 Indoor unit EEPROM parameter error 
 OFF   E2  Zero-crossing signal detection error
 OFF   E3  The indoor fan speed is operating outside of the normal range
 OFF   E5  Indoor room temperature sensor T1 is in open circuit or has short circuited
 OFF   E6  Evaporator coil temperature sensor T2 is in open circuit or has short circuited
 OFF   E7  Condenser coil temperature sensor T3 or Outdoor room temperature sensor T4 is in open circuit or has short circuited(for some models)
 ON   EC  Refrigerant leak detection
 OFF   E8  The outdoor fan speed is operating outside of the normal range (for some models)
 OFF   E9  Indoor / outdoor unit communication error(for some models)
 FLASH   P6  High pressure protection(for some models)


Ошибки KF -1802GWE KF -2302GWE

Код ошибки Описание ошибок Перевод на русский Индикация на дисплее
High Power Operation Timer Power
1 Room temperature sensor abnormal Закорочен или оборван датчик температуры воздуха *
2 Indoor heat exchanger temperature sensor abnormal Закорочен или оборван датчик температуры испарителя *
3 Indoor heat exchanger frozen Обмерзание испарителя * *
6 Instantaneous interruption of power Проблемы с электропитанием * *
7 Compressor overcurrent Перегрузка компрессора * * *
8 Fan motor locked Двигатель вентилятора не крутится *
13 Trouble with indoor unit EEPROM Ошибка микросхемы памяти на плате * * *

Ошибки KFR- 2688GW/BPE

Описание ошибок Перевод на русский Индикация на дисплее
Timer lamp Running lamp(blue) Running lamp(red) Power lamp
Indoor sensor trouble Проблема датчика температуры воздуха *
Evaporator sensor trouble Закорочен или оборван датчик температуры испарителя *
Evaporator freezing Обмерзание испарителя * *
Over hot of indoor heat exchanger Перегрев испарителя *
Communication trouble Нет связи между внутренним и внешним блоками * *
Power failure instantaneously Проблемы с питанием * *
Over current of compressor Перегрузка компрессора * * *
Fan motor trouble Неисправность двигателя вентилятора *
Outdoor sensor trouble Неисправность температурного датчика внешнего блока
Outdoor coil sensor trouble Неисправность датчика конденсора
Over current of whole system Перегрузка всей системы
No load Нет нагрузки, обрыв компрессора
Abnormal power voltage Проблема с напряжением питания
Overload of outdoor unit for cooling Перегрузка внешнего блока при охлаждении
Defrosting Режим оттаивания
IPM trouble Неисправность инверторного модуля
Data failure of outdoor EEPROM Неисправность микросхемы памяти на плате внешнего блока

★ - индикатор светится постоянно

* - индикатор мигает

Ошибки инверторных кондиционеров Ballu

KFR - 5701GW/Y2BPE

KFR - 2601GW/BPE*2

Код ошибки Описание аварии Причина неисправности
Внутренний блок
1 Room temperature sensor abnormal Thermistor short-circuited or open circuited.
2 Heat exchanger temperature sensor abnormal Thermistor short-circuited or open circuited.
3 Heat exchanger frozen
4 Heat exchanger overheated
5 Communication in trouble
8 Indoor fan in trouble
Внешний блок
1 Outdoor ambient temperature sensor abnormal Thermistor short-circuited or open circuited.
2 Abnormal temperature sensor of the outdoor heat exchanger Thermistor short-circuited or open circuited.
3 Compressor overheated Thermistor short-circuited or open circuited, or compressor overheated
4 Outdoor capillary tube A temperature sensor in trouble Thermistor short-circuited or open circuited.
5 Outdoor capillary tube B temperature sensor in trouble Thermistor short-circuited or open circuited.
6 Overcurrent Too large electric current in the outdoor unit.
7 No load Compressor not connected or the module damaged.
8 Supply voltage abnormal Too high or too low supply voltage.
9 Instantaneous interruption of power
10 Outdoor overloaded in cooling cycle
11 Defrost run is undergoing
12 Malfunction of IPM power module
13 Incorrect outdoor EEPROM data
14 Outdoor air circulation temperature sensor in trouble
15 IPM power module overheated

KFR - 28GW /BPE*2, 2801

Код ошибки Индикация на дисплее Описание проблемы Причина неисправности
Run Standby Timer Highefficiency
1 * Room temperature sensor abnormal Thermistor short-circuited or open circuited
2 * Heat exchanger temperature sensor abnormal Thermistor short-circuited or open circuited
3 * * Heat exchanger frozen
4 * Heat exchanger overheated
5 * * Communication in trouble
8 * Indoor fan in trouble

*- индикатор мигает

Код ошибки Индикация на дисплее Описание проблемы Причина неисправности
Run Standby Timer Highefficiency
1 Outdoor ambient temperature sensor abnormal

Thermistor short-circuited or open circuited

2 Outdoor heat exchanger temperature sensor abnormal Thermistor short-circuited or open circuited
3 Compressor overheated Thermistor short-circuited or open circuited, or compressor overheated
4 Outdoor capillary tube A temperature sensor in trouble Thermistor short-circuited or open circuited
5 Outdoor capillary tube B temperature sensor in trouble Thermistor short-circuited or open circuited
6 Overcurrent trouble Too large electric current in the outdoor unit
7 No load Compressor not connected or the module damaged
8 Supply voltage abnormal
9 Too high or too low supply voltage
12 Malfunction of IPM power module
13 Incorrect EEPROM data
14 Outdoor air circulation temperature sensor in trouble

★- светодиод постоянно светится

Коды ошибок кассетных кондиционеров Ballu

Внутренний блок

Тип ошибки Описание LED Flashing Примечание
1 protection Over current protection of the compressor occurs 4 times in 1 h Lamps of operation, timer, defrosting an ) flashing simultaneously at 5Hz. Whole unit is shut down. It cannot recoveunless power is cut off
2 protection Outdoor protection (absent phrase, phrase sequence and temperature protection) All lamps flashing at 5Hz Recover automatically after errors are eliminated(For T3 malfunction of 5HP, can”t recover automatically
3 error Room temperature sensor checking channel is abnormal Timer lamp flashing at 5Hz
4 error Timer lamp flashing at 5Hz Operation lamp flashing at 5Hz
5 error Condenser sensor checking channel is abnormal Defrosting lamp flashing at 5Hz
6 error Temperature fuse is melt(reserved) Operation l d timer lamp flashing at 5Hz

Внешние 3-фазные блоки мощность 3~3.5 лошадиных сил

Тип Описание LED1 LED2 LED3
Normal Off Off On
Trouble Phase sequence On Off On
Trouble Overload of current Off On On
Trouble Lack of phase On On On
Trouble Protection of pressure On On On

Внешние 3-фазные блоки мощностью 12-20 кВт

Тип Описание LED1 LED2 LED3
Trouble Phase sequence Flash Off Off
Trouble Lack of phase Flash Off Off
Trouble Protection of pressure Flash Flash Off
Trouble Overload of current Off Off Flash
Trouble Open-circuit and short-circuit trouble of T3 Off Flash Flash
Trouble Open-circuit and short-circuit trouble of T4 Off Flash Off
Trouble High temperature protection of condenser Flash Flash Flash

Ошибки кондиционеров Ballu

E1,E2,E3,E4 - закорочен или оборван температурный датчик (внутреннего или наружного блока, температуры конденсатора, температуры испарителя)

E6 - сработала защита внешнего блока

E8 - забит электростатический фильтр

P4 - ошибка по датчику испарителя, слишком низкая/высокая температура (компрессор автоматически отключается)

P5 - ошибка по датчику конденсатора, слишком низкая/высокая температура (компрессор автоматически отключается)

P6 - включился режим оттаивания или задержки по температуре внутреннего теплообменника

EA - слетела прошивка, неисправна EEPROM (определено опытным путём, замена микросхемы ПЗУ с прошивкой ошибку убирало)

Коды ошибок серий BSC; BV; BR

E1 -ошибка датчика температуры внутреннего воздуха

E2 -ошибка датчика температуры испарителя

E5 -система вошла в режим защиты по ошибке наружного блока

E6 -ошибка двигателя вентилятора внутреннего блока